TEFLON®/TEFZEL® Films and Products
| Property | Test Method | SI Units | Inch-Pound Units |
|---|---|---|---|
| Tensile Strength at break | ASTM D-882 | 21 N/mm2 | 3000 psi |
| Elongation at break | ASTM D-882 | 300% | 300% |
| Yield Point | ASTM D-882 | 12 MPa | 1700 psi |
| Elastic Modulus | ASTM D-882 | 480 MPa | 70000 psi |
| Impact Resistance | DuPont pneumatic impact tester | 6.2 x 104 | 14 in-lb/mil |
| Folding Endurance (MIT) | ASTM D-2176 | 100,000 cycles | 100,000 cycles |
| Tear Strength: Initial (Graves) |
ASTM D-1004 | 4.90 N | 500 grams |
| Tear Strength: Propagating (Elmendorf) |
ASTM D-1992 | 0.74 N | 75 grams |
| Property | Test Method | SI Units | Inch-Pound Units |
|---|---|---|---|
| Melt Point | ASTM D-3418 | 302°-310°C | 575°-590°F |
| Thermal Conductivity | (DTA) | 0.195 W/(m - K) | 1.35 Btu - in/(h - ft2 - °F) |
| Specific Heat | Cenco-Fitch | 1172 J/(kg - K) | 0.28 Btu/lb - °F) |
| Dimensional Stability | 30 min @ 150°C (302°F) | MD = 1% shrinkage TD = 1% shrinkage |
MD = 1% shrinkage TD = 1% shrinkage |
| Oxygen Index | ASTM D-2863 | 95% | 95% |
| Property | Test Method | SI Units | Inch-Pound Units |
|---|---|---|---|
| Dielectric Strength, short-time, in air @ 23°C (73°F), 6.35 mm (1/4 inch) diameter electrode, 0.79 mm (1/32 inch) radius, 60 Hz, 500 V/s rate of rise: 0.025 mm (1 mil) film |
ASTM D-149 Method A | 260 kV/mm | 6500 V/mil |
| Dielectric Constant: 25°C (77°F), 100 Hz to 1 MHz |
ASTM D-150 | 2.0 | 2.0 |
| Dissipation Factor: 25°C (77°F), 100 Hz to 1MHz |
ASTM D-150 | 0.0002-0.0007 | 0.0002-0.0007 |
| Volume Resistivity: -40° to 240°C (-40° to 464°F) |
ASTM D-257 | >1 X 1017 ohm - centimeter | >1 x 1017 - centimeter |
| Property | Test Method | SI Units | Inch-Pound Units |
|---|---|---|---|
| Moisture Absorbtion | <0.02% | ||
| Permeability, gas: Carbon Dioxide |
ASTM D-1434 | cm3/(m2 - 24h - atm)** 14 x 103 |
|
| Permeability, gas: Nitrogen |
ASTM D-1434 | cm3/(m2 - 24h - atm)** 2.0 x 103 |
|
| Permeability, gas: Oxygen |
ASTM D-1434 | cm3/(m2 - 24h - atm)** 6.7 x 103 |
|
| Permeability, vapors: Water |
ASTM E-96 | g/(m2 - d) 2 |
g/(100 in2 - 24 h) 0.13 |
| TEFLON® is chemically inert and solvent resistant to virtually all chemicals except molten alkali metals, gaseous fluorine, and certain complex halogenated compounds, such as chlorine trifluoride at elevated temperatures and pressures. | |||
| Property | Test Method | SI Units | Inch-Pound Units |
|---|---|---|---|
| Density | ASTM D-1505 | 2150 kg/m3 | 134 lb/ft3 |
| Coefficient of Friction Kinetic (film-to-steel) |
ASTM D-1894 | 0.1-0.3 | |
| Refractive Index | ASTM D-542 | 1.350 | |
| Solar Transmission | ASTM E-424 | 96% | |
| * For 0.50 mm (2 mil) film at 25°C (77°F) unless otherwise specified. ** To convert to cm3(100 in2 - 24h - atm) multiply by 0.0645. |
|||
![]() |
Click here to view our DuPont Technical Specifications TEFLON® is a registered trademark of DuPont Co. |